Abstract | In very accurate open loop lunar and deep space mission tracking the tracking station frequency standard will introduce error into the Doppler and differential Doppler measurements. The same problem is encountered in VLBI delay rate deep space tracking. To solve this problem we developed and tested a new method using frequency transferring and calibration between remote deep space tracking stations and/or VLBI stations. With the Chang¡äE-3 lunar lander and the ground application system of lunar exploration program Lunar Radio Ranging (LRR) highly accurate data were obtained of accuracy up to about several millimeters including the influence of ionosphere; the actual accuracy is now still better. High-precision observations provide opportunities for remote frequency transferring and calibration. In China we achieved two-way and three-way data exchange with the Chinese Deep Space stations at Jiamusi and Kashi. In joint research and observations of China and Russia we tested remote frequency transferring and obtained observational data. The theoretic ranging and velocity measurement program has been developed using the Naval Observatory Vector Astrometry Software (NOVAS). As a result of this program submillimeter and submillimeter per second accuracy was achieved. It allows comparative analysis of the parameters obtained from observations and from mathematic modeling. In frequency transferring we achieved a high precision level of about several mHz in the X band. |
Keyword | clock frequency Chang′E-3 lander ground observation station Lunar Radio Ranging high-accuracy da[1]ta remote frequency transferring |
DOI | 10.32876/ApplAstron.53.38-43 |
URL | 查看原文 |
Indexed By | 其他 |
Language | 俄语 |
Citation statistics | |
Document Type | 期刊论文 |
Identifier | http://ir.xao.ac.cn/handle/45760611-7/4057 |
Collection | 射电天文研究室_脉冲星研究团组 射电天文研究室 |
Affiliation | 1.National Astronomical Observatories of China, Chinese Academy of Sciences, Beijing, China; 2.University of Chinese Academy of Sciences, Beijing, China; 3.Xinjiang Astronomical Observatory, Urumqi, China; 4.Institute of Applied Astronomy of the Russian Academy of Sciences, St. Petersburg, Russia |
Recommended Citation GB/T 7714 | Li, W.,Ping, J.,Wang, M.,et al. Remote Frequency Transferring and Calibration Test in Chang'E-3 Lunar Radio Ranging[J]. Transactions of IAA RAS,2020(53):38. |
APA | Li, W.,Ping, J.,Wang, M.,Sun, J.,Marshalov, D. A.,&Bondarenko, Y. S..(2020).Remote Frequency Transferring and Calibration Test in Chang'E-3 Lunar Radio Ranging.Transactions of IAA RAS(53),38. |
MLA | Li, W.,et al."Remote Frequency Transferring and Calibration Test in Chang'E-3 Lunar Radio Ranging".Transactions of IAA RAS .53(2020):38. |
Files in This Item: | ||||||
File Name/Size | DocType | Version | Access | License | ||
Li-2020-Remote Frequ(1366KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | View Application Full Text |
Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.
Edit Comment