XAO OpenIR  > 射电天文研究室  > 脉冲星研究团组
Remote Frequency Transferring and Calibration Test in Chang'E-3 Lunar Radio Ranging
Li, W.1,2,3; Ping, J.1,2; Wang, M.1,2; Sun, J.1; Marshalov, D. A.4; Bondarenko, Y. S.4
2020
Source PublicationTransactions of IAA RAS
Issue53Pages:38
Contribution Rank3
AbstractIn very accurate open loop lunar and deep space mission tracking the tracking station frequency standard will introduce error into the Doppler and differential Doppler measurements. The same problem is encountered in VLBI delay rate deep space tracking. To solve this problem we developed and tested a new method using frequency transferring and calibration between remote deep space tracking stations and/or VLBI stations. With the Chang¡äE-3 lunar lander and the ground application system of lunar exploration program Lunar Radio Ranging (LRR) highly accurate data were obtained of accuracy up to about several millimeters including the influence of ionosphere; the actual accuracy is now still better. High-precision observations provide opportunities for remote frequency transferring and calibration. In China we achieved two-way and three-way data exchange with the Chinese Deep Space stations at Jiamusi and Kashi. In joint research and observations of China and Russia we tested remote frequency transferring and obtained observational data. The theoretic ranging and velocity measurement program has been developed using the Naval Observatory Vector Astrometry Software (NOVAS). As a result of this program submillimeter and submillimeter per second accuracy was achieved. It allows comparative analysis of the parameters obtained from observations and from mathematic modeling. In frequency transferring we achieved a high precision level of about several mHz in the X band.
Keywordclock frequency Chang′E-3 lander ground observation station Lunar Radio Ranging high-accuracy da[1]ta remote frequency transferring
DOI10.32876/ApplAstron.53.38-43
URL查看原文
Indexed By其他
Language俄语
Citation statistics
Document Type期刊论文
Identifierhttp://ir.xao.ac.cn/handle/45760611-7/4057
Collection射电天文研究室_脉冲星研究团组
射电天文研究室
Affiliation1.National Astronomical Observatories of China, Chinese Academy of Sciences, Beijing, China;
2.University of Chinese Academy of Sciences, Beijing, China;
3.Xinjiang Astronomical Observatory, Urumqi, China;
4.Institute of Applied Astronomy of the Russian Academy of Sciences, St. Petersburg, Russia
Recommended Citation
GB/T 7714
Li, W.,Ping, J.,Wang, M.,et al. Remote Frequency Transferring and Calibration Test in Chang'E-3 Lunar Radio Ranging[J]. Transactions of IAA RAS,2020(53):38.
APA Li, W.,Ping, J.,Wang, M.,Sun, J.,Marshalov, D. A.,&Bondarenko, Y. S..(2020).Remote Frequency Transferring and Calibration Test in Chang'E-3 Lunar Radio Ranging.Transactions of IAA RAS(53),38.
MLA Li, W.,et al."Remote Frequency Transferring and Calibration Test in Chang'E-3 Lunar Radio Ranging".Transactions of IAA RAS .53(2020):38.
Files in This Item:
File Name/Size DocType Version Access License
Li-2020-Remote Frequ(1366KB)期刊论文出版稿开放获取CC BY-NC-SAView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Li, W.]'s Articles
[Ping, J.]'s Articles
[Wang, M.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Li, W.]'s Articles
[Ping, J.]'s Articles
[Wang, M.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Li, W.]'s Articles
[Ping, J.]'s Articles
[Wang, M.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Li-2020-Remote Frequency Transferring and Cali.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.