XAO OpenIR  > 射电天文研究室  > 微波技术实验室
Shielding Effectiveness Experimental and Performance Analysis of Hybrid Shielding Structures for Building Walls
Liu, Qi1; Tang, Renkai1,2; Dong, Xiaoyu1; Li, Rong2; Li, Xiaofeng3; Zheng, Xianze2
2024-10-01
Conference Name14th International Symposium on Antennas Propagation and EM Theory
Source Publication14th International Symposium on Antennas Propagation and EM Theory
Conference DateOct 23-26, 2024
Correspondent Emailliuqi@xao.ac.cn
Conference PlaceHefei, PEOPLES R CHINA
CountryHefei, PEOPLES R CHINA
Publication PlaceNEW YORK
Contribution Rank1
AbstractQi Tai 110m radio Telescope (QTT) is a fully steerable single-dish radio telescope with an observing frequency coverage from 150 MHz to 115 GHz. The QTT will play an important role for fundamental research fields of radio astronomy, such as pulsars, molecular spectral lines, active galactic nuclei, and VLBI observations [1-2]. In response to the EMI (Electromagnetic Interference) coming from electronic equipment in buildings, we would like to shield the whole buildings with a hybrid shielding structure combining building walls and mesh layers. To verify the performance of the shielding structures, we conducted on three types of shielding walls (red brick, porous brick, and bubble brick) experiment and SE (Shielding Effectiveness) measurements. The testing results indicate that the SE of all three types of shielding walls can achieve 55 dB in 0.1-1GHz and 45 dB over 1 to 18 GHz respectively, which show that the performance of the hybrid shielding structure is perfect that can be employed in the buildings.
Keywordradio telescope building shielding hybrid shielding structure electromagnetic interference
DOI10.1109/isape62431.2024.10840473
Indexed ByCPCI
Language英语
ISSN979-8-3503-5313-6, 979-8-3503-5312-9
WOS IDWOS:001445524900043
Citation statistics
Document Type会议论文
Identifierhttp://ir.xao.ac.cn/handle/45760611-7/7566
Collection射电天文研究室_微波技术实验室
Affiliation1.Xinjiang Astronomical Observatory, Chinese Academy of Sciences, Urumqi 830011, China;
2.Hangzhou Dianzi University, Hangzhou 310018, China;
3.China Electronics Technology Group 33rd Research Institute, Taiyuan 030006 China
First Author AffilicationXinjiang Astronomical Observatory, Chinese Academy of Sciences
Recommended Citation
GB/T 7714
Liu, Qi,Tang, Renkai,Dong, Xiaoyu,et al. Shielding Effectiveness Experimental and Performance Analysis of Hybrid Shielding Structures for Building Walls[C]. NEW YORK,2024.
Files in This Item:
File Name/Size DocType Version Access License
Liu-2024-Shielding E(469KB)会议论文 开放获取CC BY-NC-SAView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Liu, Qi]'s Articles
[Tang, Renkai]'s Articles
[Dong, Xiaoyu]'s Articles
Baidu academic
Similar articles in Baidu academic
[Liu, Qi]'s Articles
[Tang, Renkai]'s Articles
[Dong, Xiaoyu]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Liu, Qi]'s Articles
[Tang, Renkai]'s Articles
[Dong, Xiaoyu]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Liu-2024-Shielding Effectiveness Experimental.pdf
Format: Adobe PDF
This file does not support browsing at this time
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.